ASTM E547

The ASTM E 547 - 00 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference is a testing standard that describes the procedures to determine the water penetration resistance of windows, curtain walls, skylights, and doors when water is applied using a calibrated spray apparatus while simultaneously applying cyclic static pressure to opposite sides of the test specimen.
ASTM E 547 Water Intrusion Testing
This standard is most often referenced as a laboratory test and is similar to the ASTM E 1105 Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Wall by Uniform or Cyclic Static Air Pressure. The ASTM E 1105 is specifically written for field-testing (installed fenestrations). The ASTM E 547 is also similar to the ASTM E 331 with the exception of the way air pressure is applied. The ASTM E 331 is a uniform test (consistent air pressure) and the ASTM E 547 is a cyclic test (air pressure is cycled on and off during testing).

The ASTM E 547 testing is performed by applying water to the exterior of the test specimen while lowering the pressure inside by means of an air chamber built on the inside or opposite side of the test specimen. The water spray system has nozzles spaced on a grid to deliver water in such a manner as to wet all of the test specimen uniformly, wetting those areas vulnerable to water penetration. The calibrated spray apparatus (spray-rack system) delivers water to the test specimen at a rate of 5.0 U.S. gal/ft²-h. The testing pressure differential is usually determined by the testing specifier. Most generic specifications call for a minimum testing pressure of 6.24 psf.

Building Diagnostics Group, Inc. (BDG) utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results. Our field consultants are properly trained and knowledgeable of all testing standards. BDG has extensive knowledge of most building systems and specializes in forensic water intrusion investigations. This allows us not only to properly test fenestrations on new construction projects, but if there is a test failure, we can pinpoint the cause of the failure and provide accurate recommendations to achieve successful testing results. Failures during quality assurance (new construction) testing can result in unnecessary delays that impact your bottom line.

If you are looking for a reputable second or third party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact Building Diagnostics Group, Inc. (BDG) today. We provide testing services throughout the United States from our headquarters located in Atlanta, GA.

To request a proposal for services, contact us at RFP@buildingdiagnosticsgroup.com or call 888.317.4568.
 

Client Extranet
© 2011 Building Diagnostics Group - All Rights Reserved  |  Atlanta, Georgia  |  Nationwide
Tel: (404) 946-9939  |  Toll Free/Fax: (888) 317-4568  |  Email Inquiries  |  Privacy Policy  |  Terms of Use  |  Sitemap

Building Diagnostics  |  Infrared Inspection | Thermographic Building Inspection  |  Water Testing  |  Exterior Cladding Surveys
Water Infiltration Detection & Documentation  |  Commercial Roof Surveys  |  Cell Fill (CMU) Evaluations   |  Indoor Air Quality Testing  |  Energy Audits

isoosi web directory