Curtain Wall Testing
Below are the types and links for additional details to the various performance specifications:

ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
ASTM E 547 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference
ASTM E 783 - Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors
ASTM E 1105 - Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference
ASTM C 1601 - Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces
ASTM C 1715 - Standard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems
ASTM E 2128 - Standard Guide for Evaluating Water Leakage of Building Walls
AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems
AAMA 502 - Voluntary Specification for Field Testing of Newly Installed Fenestration Products
AAMA 503 - Voluntary Specification for Field Testing of Newly Installed Storefronts, Curtain Walls and Sloped Glazing Systems
AAMA 511 - Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products
Building Diagnostics Group, Inc. (BDG) utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results. Our field consultants are properly trained and knowledgeable of all testing standards. BDG has extensive knowledge of most building systems and specializes in forensic water intrusion investigations. This allows us to not only properly test fenestrations on new construction projects, but if there is a test failure, we can pinpoint the cause of the failure and provide accurate recommendations to achieve successful testing results. Failures during quality assurance (new construction) testing can result in unnecessary delays that can impact your bottom line.
If you are looking for a reputable third party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact Building Diagnostics Group, Inc. (BDG) today. We provide third party field fenestration testing throughout the United States from our main office located in Atlanta, GA.
To request a proposal for services, contact us at RFP@buildingdiagnosticsgroup.com or call 888.317.4568.
|