Contact Building Diagnostics Group
Contact Building Diagnostics Group
Follow BDG on Twitter

Memphis Water Testing

Building Diagnostics Group, Inc (BDG) is the leader in quality assurance and forensic water intrusion testing. We specialize in commercial, multi-family, and industrial projects. Contact our Atlanta office today for more information.

Memphis Water Intrusion TestingWater penetration field testing will determine the quality of work of subcontractors and ensure their accountability and will also ensure that proper specifications were followed during the construction of your Memphis property. Typically these services are performed for quality assurance or new building commissioning for multi-family and commercial buildings. On existing Memphis area buildings, we perform forensic water testing to determine if fenestrations (windows/doors/penetrations) are properly flashed and sealed to prevent water infiltrations. In addition, these same tests can be used to identify building failures for cause & origin investigations of water penetration.

Our expertise is water damage cause & origin investigations in the Memphis area. We use our specialized calibrated water spray rack equipment to recreate reported water intrusions and accurately identify failure points in the building envelope. We actually recreate a simulated rainfall event in a controlled manner to find the exact source of the water infiltration, a procedure sometimes referred to as forensic water infiltration testing. This systematic approach will identify the cause & origin of the failure as well as provide accurate documentation so proper repair procedures can be executed. Following the repairs, we typically retest the areas to determine if the repairs were performed correctly and verify that the water intrusion has been repaired.

Building Diagnostics Group specializes in third party water infiltration field testing in the Memphis area. We perform these services on windows, curtain walls, and storefront systems for water penetration during the construction phase or complete forensic water penetration of installed windows, doors, and wall systems. BDG testing professionals use only the highest quality testing equipment available in order to complete testing in accordance with either the American Architectural Manufacturers Association (AAMA) or American Society for Testing and Materials (ASTM) testing protocols. We provide these services all across the nation, including Memphis. Our knowledgeable staff is ready to take on your next project to meet your product testing needs. When you really need to know... call us!

Memphis ASTM Water TestingBelow are the types of testing we perform to published standards in the Memphis area:

Memphis ASTM E1105 - 00(2008) - Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference

Memphis ASTM E331 - 00 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

Memphis ASTM E547 - 00 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference

Memphis ASTM E2128 - 01a - Standard Guide for Evaluating Water Leakage of Building Walls

Memphis AAMA 502-08 - Voluntary Specification for Field Testing of Newly Installed Fenestration Products

Memphis AAMA 511-08 - Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products

Memphis AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems

Building Diagnostics Group also performs modified versions of the above tests utilizing our high-resolution infrared camera equipment to identify water intrusions non-destructively. Although this does not meet many of the static pressure type standardized testing above, we never exceed the design pressure of a product or building component during these tests. The modified versions can be used to identify potential failures without expensive destructive testing, as most of the standardized testing requires disassembly of the building components. Read our published white paper, "Water Infiltration Testing Using Infrared Memphis ASTM Water Intrusion TestingThermography".

The quality of the initial field evaluation directly affects the quality and performance of repairs, as outlined in the specification documents. The time and expense of performing an initial, well-focused evaluation will save the building owner/manager money in the long run and result in repairs that extend the service life of your Memphis building.

We offer competitive flat rate fees for water testing in the Memphis area. Contact our office today at (888) 317-4568 for a free proposal based on your project requirements.

Our office in Atlanta serves Memphis and the surrounding areas, including; Memphis, Marion, West Memphis, Germantown, Southaven, Olive Branch, Collierville, Bartlett, Millington, Arlington, and Jonesboro.

 

Memphis AAMA Water Testing | Memphis ASTM Water Testing | Memphis Water Intrusion Diagnostics | Memphis Forensic Water Testing
Memphis ASTM E1105 | Memphis ASTM E331 | Memphis ASTM E547 | Memphis ASTM E2128 | Memphis AAMA 502
Memphis AAMA 511 | Memphis AAMA 501

Client Extranet
© 2011 Building Diagnostics Group - All Rights Reserved  |  Atlanta, Georgia  |  Nationwide
Tel: (404) 946-9939  |  Toll Free/Fax: (888) 317-4568  |  Email Inquiries  |  Privacy Policy  |  Terms of Use  |  Sitemap

Building Diagnostics  |  Infrared Inspection | Thermographic Building Inspection  |  Water Testing  |  Exterior Cladding Surveys
Water Infiltration Detection & Documentation  |  Commercial Roof Surveys  |  Cell Fill (CMU) Evaluations   |  Indoor Air Quality Testing  |  Energy Audits

isoosi web directory